National Instruments FP-QUAD-510 User Manual

Page of 12
FP-QUAD-510
10
www.ni.com
As with any hazardous voltage wiring, make sure that all 
wiring and connections meet applicable electrical codes and 
common sense practices. Mount terminal bases in an area, 
position, or cabinet that prevents accidental or unauthorized 
access to wiring that carries hazardous voltages.
The isolation of the FP-QUAD-510 is certified as 
double-insulated for normal operating voltages of 250 Vrms. 
Do not use the FP-QUAD-510 as the only isolating barrier 
between human contact and working voltages of more than 
250 Vrms.
Channel Operation Summary
Table 3 summarizes the functionality of each of the FP-QUAD-510 
channels as accessed through FieldPoint Explorer or other 
software.
Table 3.  FP-QUAD-510 Channel Operation Summary
Channel 
No.
Channel Description
Type
Range
0
Axis 0 Position LSW
Count Input
0–65535
1
Axis 1 Position LSW
Count Input
0–65535
2
Axis 2 Position LSW
Count Input
0–65535
3
Axis 3 Position LSW
Count Input
0–65535
4
Axis 0 Position MSW
Count Input
0–65535
5
Axis 1 Position MSW
Count Input
0–65535
6
Axis 2 Position MSW
Count Input
0–65535
7
Axis 3 Position MSW
Count Input
0–65535
8
Axis 0 Velocity
Analog Input
8 ranges
9
Axis 1 Velocity
Analog Input
8 ranges
10
Axis 2 Velocity
Analog Input
8 ranges
11
Axis 3 Velocity
Analog Input
8 ranges
12
Axis 0 Index Active 
Discrete Input
Boolean
13
Axis 1 Index Active
Discrete Input
Boolean
14
Axis 2 Index Active
Discrete Input
Boolean
15
Axis 3 Index Active
Discrete Input
Boolean