Page 6
NDA-30115  Revision 1.0
Architecture
Property Management System - Communication Interface
The messages (but not the control codes or start sequence) sent between the NEAX 
and the PMS must have header and trailing sections as defined in the following 
format:
Table 2-3  Base Message Format
The message format breaks down as follows:
STX -- Start of text block. (One byte - 02H.)
SA -- System Address. (One byte - ‘1’ [31H].)
UA -- I/O Unit Address. (One byte - ‘!’ [21H].)
EI -- Entry Index. (One byte - ‘L’ [4CH].)
FTC -- Feature Code. (See below.) A list is provided in 
.
MSC -- Message Counter. This represents the length of the message. The count 
of characters starts at the FTC field and ends at the last character of the body of 
the message, not including the ETX. If the ETX character does not immediately 
follow the character specified by the message counter, an invalid message is 
assumed.
FC -- Function Code. This specifies the individual operation and processing for 
the feature designated by the Feature Code (FTC). A list is provided in 
ETX -- End of text block. (One byte - 03H.)
BCC -- Block Check Code. This is computed by an exclusive OR of the 
message from the SA to the ETX (inclusive). Detection of an STX starts the 
computation (but the STX is not included). Detection of an ETX stops the 
computation (and the ETX is included). (One byte.)
Feature Codes range in value from 00 to FF (hex). These codes define the “Major 
Category Codes” for service features.
Codes from 80 to FF are used as “Violation Codes”. When a specific message 
received from the PMS cannot be processed for some reason, 80 (hex) is added to 
the received Feature Code so that it will be handled as a Violation Code. If the 
NEAX regards a text as a Violation Code, the system data of the NEAX may be 
assigned so that a text of this type is returned to the PMS. Therefore, when the PMS 
has received a Violation Code, provisions should be made for the PMS to print out 
this violation.
Block Check Code Range
02H ‘1’
03H xx
‘!’
...
0
1
2
3
4
6
8
9
STX
SA
UA
EI
FTC
MSC
FC
Message
ETX BCC
Message Count Range
‘L’