NEC NDA-30115-001 User Manual

Page of 116
Page 42
NDA-30115  Revision 1.0
Message Formats
Property Management System - Communication Interface
Check Out
Figure 4-11   Check Out
The only message field is the extension number who is being checked out. If the 
extension number is less than six digits, left justify the number and fill the 
remaining bytes with space (20H) characters. The Room Status is set to “Out” and 
Room Cut-Off is set.
Check Out 
Message Report
Figure 4-12   Check Out Message Waiting Lamp Report
Message fields are:
FC-- There are two functions: (FTC-FC)
16-5 -- Check Out Message Waiting Lamp Off Report
16-6 -- Check Out Message Waiting Lamp On Report
Extension -- Extension number. If the extension number is less than six digits, 
left justify the number and fill the remaining bytes with space (20H) characters.
‘2’
‘1’ ‘6’
‘1’
‘1’
Extension
0
1
2
3
4
6
8
9
15
16
STX
SA
UA
EI
FTC
MSC
FC
6
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
**
** Multiple Function Codes use this message. See below.
‘1’ ‘6’
‘1’
‘1’
Extension
0
1
2
3
4
6
8
9
15
16
STX
SA
UA
EI
FTC
MSC
FC
6
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC