NEC NDA-30115-001 User Manual

Page of 116
NDA-30115  Revision 1.0
Page 53
Property Management System - Communication Interface
Message Formats
Wake Up/Group Announcement
The Function Codes are as follows:
19-1 -- Wake Up Setting (Sent by NEAX)
19-2 -- Wake Up Cancellation (Sent by NEAX)
19-3 -- Wake Up Execution Result
19-4 -- Wake Up Setting (Sent by PMS)
19-5 -- Wake Up Cancellation (Sent by PMS)
19-6 -- Group Announcement Setting (Sent by NEAX)
19-7 -- Group Announcement Cancellation (Sent by NEAX) 
19-8 -- Group Announcement Execution Result
19-9 -- Group Announcement Setting (Sent by PMS)
19-A -- Group Announcement Cancellation (Sent by PMS)
These messages are used by both the Model 60 and the Model 90 versions.
Wake Up Setting 
(NEAX)
Figure 4-25   Wake Up Setting (NEAX)
Message fields are:
Extension -- Extension number. If the extension number is less than six digits, 
left justify the number and fill the remaining bytes with space (20H) characters.
Time -- Time for which a wake up call is set. Format used is HHMM using 
military time.
Source -- Code for the source of the wake up setting. Possible values are:
1 -- Guest Extension.
2 -- Attendant.
3 -- Administration Extension.
4 -- Property Management System.
0
1
2
3
4
6
8
9
15
STX
SA
UA
EI
FTC
MSC
FC
6
4
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
1
19
20
21
‘1’
‘9’ ‘1’
‘6’
‘1’ Extension
Time
Source