NEC NDA-30115-001 User Manual

Page of 116
Page 58
NDA-30115  Revision 1.0
Message Formats
Property Management System - Communication Interface
Group 
Announcement 
Setting (NEAX)
Figure 4-30   Group Announcement Setting (NEAX)
Message fields are:
Group ID -- Group number to set. If the group number is less than six digits, left 
justify the number and fill the remaining bytes with space (20H) characters.
Time -- Time for which a group announcement call is set. Format used is 
HHMM using military time.
Source -- Code for the source of the group announcement setting. Possible 
values are:
1 -- Guest Extension.
2 -- Attendant.
3 -- Administration Extension.
4 -- Property Management System.
Type -- Code for the type of announcement. The values for the code are 
determined by the site, and therefore cannot be listed here.
Type
0
1
2
3
4
6
8
9
15
STX
SA
UA
EI
FTC
MSC
FC
6
4
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
1
1
19
20
21
22
‘1’
‘9’ ‘1’
‘7’
‘6’ Group ID
Time
Source