NEC NDA-30115-001 User Manual

Page of 116
Page 70
NDA-30115  Revision 1.0
Message Formats
Property Management System - Communication Interface
Room Key Status 
Change
Figure 4-44   Room Key Status Change
Message fields are:
Extension -- Extension number. If the extension number is less than six digits, 
left justify the number and fill the remaining bytes with space (20H) characters.
Key -- Room key status:
0 -- Key is in the key rack.
1 -- Key is not in the key rack.
Extension Report
This message is used by the NEAX to notify the PMS of the addition of an 
extension to the system or a deletion of an extension from the system. Both the 
Model 60 and the Model 90 version use these messages. The two messages used 
are:
17-E -- Extension Delete Report
17-F -- Extension Assignment Report
Extension Delete 
Report
Figure 4-45   Extension Delete Report
Message fields are:
Extension -- Extension number. If the extension number is less than six digits, 
left justify the number and fill the remaining bytes with space (20H) characters.
Blank -- Field contains two space (20H) characters.
‘6’
‘1’ ‘1’
‘2’
‘4’ Extension
Key
0
1
2
3
4
6
8
9
15
16
17
STX
SA
UA
EI
FTC
MSC
FC
6
1
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
‘1’
‘7’ ‘1’
‘3’
‘E’ Extension
Blank
0
1
2
3
4
6
8
9
15
17
18
STX
SA
UA
EI
FTC
MSC
FC
6
2
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC