NEC NDA-30115-001 User Manual
Page 70
NDA-30115 Revision 1.0
Message Formats
Property Management System - Communication Interface
Room Key Status
Change
Change
Figure 4-44 Room Key Status Change
Message fields are:
•
Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
left justify the number and fill the remaining bytes with space (20H) characters.
•
Key -- Room key status:
•
0 -- Key is in the key rack.
•
1 -- Key is not in the key rack.
Extension Report
This message is used by the NEAX to notify the PMS of the addition of an
extension to the system or a deletion of an extension from the system. Both the
Model 60 and the Model 90 version use these messages. The two messages used
are:
extension to the system or a deletion of an extension from the system. Both the
Model 60 and the Model 90 version use these messages. The two messages used
are:
•
17-E -- Extension Delete Report
•
17-F -- Extension Assignment Report
Extension Delete
Report
Report
Figure 4-45 Extension Delete Report
Message fields are:
•
Extension -- Extension number. If the extension number is less than six digits,
left justify the number and fill the remaining bytes with space (20H) characters.
left justify the number and fill the remaining bytes with space (20H) characters.
•
Blank -- Field contains two space (20H) characters.
‘6’
‘1’ ‘1’
‘2’
‘4’ Extension
Key
0
1
2
3
4
6
8
9
15
16
17
STX
SA
UA
EI
FTC
MSC
FC
6
1
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
‘1’
‘7’ ‘1’
‘3’
‘E’ Extension
Blank
0
1
2
3
4
6
8
9
15
17
18
STX
SA
UA
EI
FTC
MSC
FC
6
2
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC