NEC NDA-24233 User Manual
NDA-24233 Issue 2
Page 4-1
VisuaLink 128/384 Engineering Guide
Error Response Table
4: Error Response Table
If a command input from console is not understandable or has a different configuration, an error response is
transmitted to the console. Error responses are shown in the following table.
transmitted to the console. Error responses are shown in the following table.
Table 4-1: Error Response Table (1/2)
ERR Number
Contents
Countermeasures
ERR01
Syntax error.
Check the format of a command
ERR05
It is a command that cannot be
accepted by the current system.
accepted by the current system.
Check current system settings
ERR06
It is during an initial setting.
Try again
ERR07
Time out
Try again
ERR09
It is a command that cannot be
executed in the current mode.
executed in the current mode.
Check current system settings
ERR10
A camera is not connected.
Check current system settings
ERR11
This is not a preset camera.
Check current system settings
ERR12
The displayed screen is not a received
video, so a remote camera control
cannot be performed.
video, so a remote camera control
cannot be performed.
Check current system settings
ERR16
NEC specific features cannot be
performed.
performed.
Check current system settings
ERR17
The remote terminal has no capability
to perform this command.
to perform this command.
It is impossible in the current configuration
ERR18
Cannot be controlled for it is set for a
pass-through mode.
pass-through mode.
VL is in remote maintenance.
ERR20
MLP port has not yet been established.
Check communication status and execute
command again.
command again.
ERR21
Error in data speed setting combination.
Check current system settings
ERR22
The local site is not participating in the
conference room.
conference room.
Check communication status
ERR23
A specified conference room is not
participating in a multi-point
conference.
participating in a multi-point
conference.
Check communication status and execute
command.
command.
ERR24
Multi-point command is either invalid or
overlapping.
overlapping.
Check communication status and execute
command.
command.
ERR26
VL is not in multi-point conference.
Check communication status and execute
command.
command.
ERR32
It cannot be set in the current network.
Check communication status and execute
command.
command.
ERR37
The remote terminal cannot be
recognized as a NEC model.
recognized as a NEC model.
Check communication status and execute
command.
command.
ERR38
Local loopback cannot be done since it
is processing a remote loopback.
is processing a remote loopback.
Execute a command after release of the
remote loopback.
remote loopback.
ERR 40
It is in a telephone communication
mode.
mode.
Command to execute is impossible.
ERR41
Network in use is not an ISDN line.
Check current system settings
ERR42
No incoming call
Check communication status and execute
command.
command.
ERR43
Currently originating a call.
Check communication status and execute
command.
command.
ERR44
Incoming call
Check communication status and execute
command.
command.
ERR45
On line.
Check communication status and execute
command again.
command again.