NEC NDA-24233 User Manual
Page 3-36
NDA-24233 Issue 2
Console Command List
VisuaLink 128/384 Engineering Guide
3.8 Alarm Related Command
CALM
Read Alarm Status (1 of 2)
8-1
Description:
Acquires alarm status. This is used to check the information of a generated
alarm and the loopback status.
alarm and the loopback status.
Command Format:
CALM
Response:
Normal Response: p1 p2 p3 p4 p5 p6 OK
p1:
00-FF :
CPU/ VIDEO alarm
p2:
00-FF :
LINE alarm
p3:
00-FF :
H221 alarm
p4:
00-FF :
Bonding alarm
p5:
00-FF :
TEST status
p6:
00-FF :
TEST status 2
p1:
CPU/VIDEO alarm
D0:
CPU alarm 0:
normal
1:
abnormal
D1:
FAN alarm 0:
normal
1:
abnormal
D2-3:
Unused 0:
fixed
D4:
VIDEO alarm 0:
normal
1:
input cut
D5-7: Unused
0:
fixed
p2:
LINE alarm
D0-3: Unused
0: fixed
D4: Line 1 SYNC alarm 0: normal 1:
abnormal
D5:
Line 2 SYNC alarm 0: normal 1:
abnormal
D6:
Line 3 SYNC alarm 0: normal 1:
abnormal
D7: Unused
0: fixed
p3:
H221 alarm
D0:
REC alarm 0:
normal
1:
abnormal
D1:
CRC alarm 0:
normal
1:
abnormal
D2-7: Unused
0:
fixed
D7 D6 D5 D4 D3 D2 D1 D0
D7 D6 D5 D4 D3 D2 D1 D0
D7 D6 D5 D4 D3 D2 D1 D0