3.8  Alarm Related Command
CALM
Read Alarm Status (1 of 2)
8-1
Description:
Acquires alarm status.  This is used to check the information of a generated 
alarm and the loopback status.
Command Format:
CALM
Response:
Normal Response: p1 p2 p3 p4 p5 p6 OK
p1:
00-FF : 
CPU/ VIDEO alarm
p2:
00-FF : 
LINE alarm
p3:
00-FF : 
H221 alarm
p4:
00-FF : 
Bonding alarm
p5:
00-FF : 
TEST status
p6:
00-FF : 
TEST status 2
p1:
CPU/VIDEO alarm
D0: 
CPU alarm   0: 
normal 
1: 
abnormal
D1: 
FAN alarm   0: 
normal 
1: 
abnormal
D2-3: 
Unused 0:
fixed
D4: 
VIDEO alarm 0: 
normal 
1:
 input cut
D5-7:  Unused  
0:
fixed
p2:
LINE alarm
D0-3: Unused  
0: fixed
D4:  Line 1 SYNC alarm 0:  normal  1: 
abnormal
D5:
Line 2 SYNC alarm 0:  normal  1: 
abnormal
D6:
Line 3 SYNC alarm 0:  normal  1: 
abnormal
D7:  Unused  
0: fixed
p3:
H221 alarm
D0: 
REC alarm   0: 
normal 
1: 
abnormal
D1: 
CRC alarm   0: 
normal 
1: 
abnormal
D2-7:  Unused  
0:
fixed
D7 D6 D5 D4 D3 D2 D1 D0
D7 D6 D5 D4 D3 D2 D1 D0
D7 D6 D5 D4 D3 D2 D1 D0