NEC NDA-24233 User Manual
Page 3-40
NDA-24233 Issue 2
Console Command List
VisuaLink 128/384 Engineering Guide
3.11 Serial Port Control Command
SSIO
Setting Serial Port
11-1
RSIO
Checking Serial Port Setting
11-2
Description:
VisuaLink is equipped with two serial ports, and four possible settings:
T120 data conference
Camera control
External console control
User data (Not compliant to T.120)
Camera control
External console control
User data (Not compliant to T.120)
Command Format:
SSIO p1
p1: 1
Serial 1 = T120
Serial 2 = Console
2
Serial 1 = Camera
Serial 2 = Console
3
Serial 1 = T120
Serial 2 = Camera
4
Serial 1 = Console
Serial 2 = Camera
5
Serial 1 = User data
Serial 2 = Console
6
Serial 1 = User data
Serial 2 = Camera
Response:
Normal Response OK
Error Response:
Description:
Checks the current serial port configuration.
Command Format:
RSIO
Response:
Normal Response p1 OK
p1: 1
Serial 1 = T120
Serial 2 = Console
2
Serial 1 = Camera
Serial 2 = Console
3
Serial 1 = T120
Serial 2 = Camera
4
Serial 1 = Console
Serial 2 = Camera
5
Serial 1 = User data
Serial 2 = Console
6
Serial 1 = User data
Serial 2 = Camera
Error Response: