NEC NDA-24233 User Manual

Page of 124
Page 3-48
NDA-24233 Issue 2
Console Command List
VisuaLink 128/384 Engineering Guide
RMST
Read Multi-point Conference Operation Status (NEC Specific)
16-2
Description:
Acquires a status of a multi-point conference status when in activated for 
NEC specific multi-point conference.
Command Format:
RMST p1 p2 p3 p4 p5 p6 ............ p18
p1:
1-14 
local site conference number
p2:
0000-FFFF  : 
conference participating status 1: participate 
0: not participate
p3:
0000-FFFF  : 
terminal connection status 1: connect 
0: not connected
p4:
0000-FFFF  : 
audio switch status 1: switch 0: not switch
p5:
0000 : 
fixed
p6
0000 : 
fixed
p7:
1-14 
operator conference room number 00: no 
operator
p8:
1-14 
conference room number of the originator of 
multiple address transmission
p9:
1-14 
conference room number of a location 
receiving multiple address transmission.
p10: 1-14 
conference room number of the originator of a 
transmission at a specify video reception.  It is 
not a specific video reception if it is 00.
p11: 0 : 
fixed
p12: 0 : 
fixed
p13: 0 : 
fixed
p14: 0 : 
fixed
p15: 0 : 
fixed
p16: 0 : 
fixed
p17: 1111 : 
fixed
p18: 0-1 
local office in transmission  0: not transmitting 
1: transmitting
Note 1:
When p1 = 0, a local site withdraw from a multi-point 
conference.
Note 2:
Bit assignment of 0000-FFFF is as 
follows:
X
X 14 13 12 11 10
9
8
7
6
5
4
3
2
1
Master Only
Slave                                                Master