Installing ISDN BRI hardware for line applications
25
shows the cable
connection between the system and the MDF.
1
Determine the number of NE-A25B cables needed to connect one
module to the MDF.
2
Label each end of the cable specifying the module number, the
connector name (A, B, C), and the card type (SILC or UILC).
3
Plug one end of a cable into the appropriate connector on the I/O
panel at the rear of the module. Plug the other end of the cable into
the corresponding connector on the MDF.
4
Properly identify cables on the MDF. For example, plug the cable into
connector A on the I/O panel and into the connector labeled A on the
MDF, if an SILC or UILC is installed in slot 0 of an IPE module.
5
Repeat steps 2 through 4 for all cables in that module.
6
Repeat steps 1 through 5 for all modules containing SILCs and/or
UILCs.
7
Lay all the cables neatly and fasten them with cable ties.
8
Label the MDF, as necessary, using
through
beginning on
—End—