Nortel Networks NN43001-318 User Manual

Page of 108
82
Configuring ISDN BRI hardware
Error Code
Number
Description
>>32<<
No valid data SPID.
>>90<<
Restricted power mode in use. Lower ringer and speaker
phone volumes apply.
Connecting the ISDN BRI trunks (for trunking applications)
For trunking applications, two procedures are required to connect the ISDN
BRI trunks:
Step
Action
1
Connect the system cables to the cross-connect terminal. See
.
2
Cross-connect the DSLs at the cross-connect terminal. See
.
—End—
Procedure 25
Connecting the system cables to the cross-connect terminal
Step
Action
Each card slot equipped with an SILC or UILC requires one NE-A25B
25-pair connector cable. The cables connect to the connectors at the
bottom of the cabinet or at the rear of the MG 1000S. Each connector
is assigned to its corresponding card slot (for example, connector J8 is
assigned to card slot 8).
1
Remove the connector retaining bar from the connector panel
in the lower part of each cabinet or MG 1000S. See
and
on
and
on
2
Connect an NE-A25B cable to each connector associated with
a card slot containing an SILC or UILC circuit card. See
and
on
and
Nortel Communication Server 1000
ISDN Basic Rate Interface Installation and Commissioning
NN43001-318
01.02
Standard
Release 5.0
20 June 2007
Copyright © 2003-2007, Nortel Networks
.