CallPilot server installation
3
Install the power cords to all devices, but plug them only into the
receptacle, not into the end device. The devices requiring power are:
1005r server — two power cords, redundant power supplies
600r server — one power cord
monitor — one power cord
tape drive — one power cord
ELAN subnet Ethernet switch or hub — one power cord
Nortel server subnet Ethernet switch or hub — one power cord
Note: The single-point ground (SPG) required by the system
can be an isolated ground (IG) bus or AC equipment ground
(ACEG) bus in the service panel or transformer. The system
must be connected to a safety ground or protective earth in
accordance with NEC requirements. For international use, the
system must be connected to safety ground or protective earth in
accordance with Paragraph 2.5 of EN60950/IEC950.
4
Check the version of your MPB96 card or cards before proceeding.
The versions are identified as follows:
The NTRH40CA MPB96 board has three RJ-45 connectors on
its faceplate. If you have an NTRH40CA, proceed to step 5.
The NTRH40AA MPB96 board has a single DB-44 connector on
its faceplate. The MPB96 connects to the MGate using a DS30X
cable. If you have an NTRH40AA, proceed to step 6.
5
Install and connect the DS30 cables from the switch MGATE card
to the CallPilot MPB96. There is no restriction as to which cable is
connected first, as the NTRH40AC MPB96 can get its timing from
any of the three RJ-45 ports.
The RJ-45 connectors in the top MPB96 card are numbered
from 1 to 3 starting at the right side of the server’s back panel
(next to the power supplies) They are cabled to MGate cards
1 to 3 respectively
If there are three MPB96 cards in your server, the RJ-45
connectors in the middle card are cabled (from right to left) to
MGate cards 4 to 6. The bottom MPB96 card is not connected
to the switch.
Continue with
Nortel CallPilot
Quickstart Guide
NN44200-313