Nortel Networks 201i User Manual

Page of 178
Installing the 201i server in a large Meridian 1 system
Standard 1.07
58
CallPilot
Removing the backplane (tip and ring) 
cables
Introduction
You must remove the Meridian 1 backplane (tip and ring) cables that are 
associated with the slots occupied by the 201i server so that you can install 
the following cables:
„
NTRH3501 backplane (tip and ring) cable
The NTRH3501 cable offers more network throughput than the cable 
that is already installed on the Meridian 1. This cable is connected to the 
backplane connectors and I/O panel slot associated with the left slot.
„
NTRH1408 intermediate SCSI cable 
The NTRH1408 intermediate SCSI cable routes the SCSI device 
connection away from the 201i server faceplate so that an external SCSI 
device can remain permanently connected. This cable is connected to the 
I/O panel only. The backplane connectors associated with the right slot 
are left vacant.
These cables are supplied with the 201i server.
Before you begin
Note: For information about slot and rear bulkhead wiring and powering off 
the shelf, refer to the Meridian 1 System Installation and Maintenance 
Guide
 (NTP 553-3001-210).
DANGER
Risk of electrical shock
Ensure that the shelf is powered off before you remove the 
backplane cables.