Nortel Networks 201i User Manual
Installing the 201i server in an Option 11C or Option 11C Mini
Standard 1.07
72
CallPilot
Installing the 201i server in the Option 11C
or Option 11C Mini switch
or Option 11C Mini switch
Introduction
The 201i server occupies physical and electrical slots. The 201i server must
be installed in two peripheral equipment slots as follows:
be installed in two peripheral equipment slots as follows:
To position the 201i server on the switch shelf
1 Remove the front panel of the switch.
Note: On the Option 11C Mini, do the following:
a. Loosen the spring-loaded clips.
b. Slide the cover to the left.
c. Pull the cover up to remove it from the cabinet.
Switch
Eligible slots
Option 11C
Slots 1 through 9
Note: Both of the server backplane connectors
must be installed in slots 1 through 9 to receive
proper power. Neither connector can reside in slot
10.
must be installed in slots 1 through 9 to receive
proper power. Neither connector can reside in slot
10.
Option 11C Mini
A pair of consecutive slots in any cabinet
Note: You cannot install the 201i server in slots 0
or 4, because these slots are dedicated to other
cards. For more information about cards and slots,
refer to the Option 11C Mini documentation.
or 4, because these slots are dedicated to other
cards. For more information about cards and slots,
refer to the Option 11C Mini documentation.