Nortel Networks Option 11C User Manual

Page of 546
Transmission parameters
Page 169 of 544
Impulse Noise
Impulse noise is defined as noise bursts or spikes that exceed normal peaks of 
idle-channel noise. Impulse noise is measured by counting the number of 
spikes exceeding a pre-set threshold; it is the number of counts above 55 
dBm0 during a five minute interval, under fully loaded busy hour PBX traffic 
conditions.
Variation of gain versus level
The variation of gain verses level (tracking error) measures how closely 
changes in input levels causes corresponding changes in output levels.
The tracking error is measured in decibels and is defined as the deviation in 
gain or loss through a range of input level relative to the gain or loss at the 
reference frequency and level of 0 dBmO.
The two methods of measuring the tracking error are listed below.
Method 1
When a noise signal as defined in CCITT, recommendation 0.131 is applied 
at the input of any interface, the gain versus level deviation at the output 
meets the limits set out in Table 47.
Alternatively, when a sine wave input in the frequency range 700 - 1100 Hz 
is applied at the input of any interface, the gain vs level deviation at the output 
meets the limits given in Table 48.
Table 46
Impulse Noise
Time
Level
Counts
5 Minutes
>55 dBmO
0
Table 47
Variation of gain versus level method 1
Input Level dBm0
Gain Variation dB
-55 to -10
+/-0.5