Nortel Networks Option 11C User Manual

Page of 546
SDI ports
Page 231 of 544
The baud rates available on all three ports are 300, 600, 1200, 2400, 4800, and 
19200 baud.
NTAK03 TDS/DTR card
Table 74 shows the default settings.
The NTAK03 TDS/DTR card is replaced by the NTDK20 SSC card in 
Option 11C, and the NTDK97 MSC in Option 11C Mini. However, it is still 
supported and can be retained to gain access to extra ports.
Connecting to the ports
The methods by which external devices may be connected to the TDS/DTR 
card are:
Use the NTAK19EC two port SDI cable. The NTAK19EC cable does not 
have to be terminated at the cross connect terminal since it is equipped 
with connectors.
Use the NE-A25-B cable and terminate it at the cross connect terminal. 
Tables 75 and 76 give the pinouts for the TDS/DTR card.
Table 73
Default port configuration
TTY Number
Card
Port
Use
Configuration
0
0
0
MTC/SCH/BUG
1200/8/1/NONE
0
1
MTC/SCH/BUG
1200/8/1/NONE
0
2
CTY
1200/8/1/NONE
Table 74
Default port configuration
TTY Number
Card
Port
Use
Configuration
0
0
0
MTC/SCH/BUG
1200/8/1/NONE
0
1
MTC/SCH/BUG
1200/8/1/NONE
0
2
CTY
1200/8/1/NONE