Nortel Networks Option 11C User Manual

Page of 546
Page 374 of 544
NT8D09 Analog Message Waiting Line Card
Technical summary
Analog line interface
Input impedance
The impedance at tip and ring is 600 ohms with a return loss of:
20 dB for 200-500 Hz
26 dB for 500-3400 Hz
Insertion loss
On a station line-to-line connection, the total insertion loss at 1 kHz is 
6 dB + 1 dB. This is arranged as 3.5 dB loss for analog to PCM, and 2.5 dB 
loss for PCM to analog.
Frequency response
The loss values in Table 110 are measured relative to the loss at 1 kHz.
Message channel noise
The message channel noise C-weighted (dBrnC) on 95 percent of the 
connections (line to line) with both ends terminated in 600 ohms does not 
exceed 20 dBrnC.
Table 110
NT8D09 Analog Message Waiting Line Card frequency response
Frequency
Minimum
Maximum
  60 Hz
20.0 dB
--
200 Hz
  0.0 dB
5.0 dB
300 Hz
-0.5 dB
1.0 dB
3000 Hz
-0.5 dB
1.0 dB
3200 Hz
-0.5 dB
1.5 dB
3400 Hz
0.0 dB
3.0 dB