Physical characteristics
In Option 11C systems the NT8D15 E&M Trunk Card is installed in slots 1 
through 10 of the Main cabinet, or in slots 11 through 50 of the Expansion 
cabinets. 
In Option 11C systems equipped with Meridian Mail, the Universal Trunk 
line card cannot be installed in slot 10 of the main cabinet.
Each card provides four circuits. Each circuit connects with the switching 
system and with the external apparatus by an 80-pin connector at the rear of 
the pack. 
Each trunk circuit on the card connects to trunk facilities by tip an ring leads 
which carry voice, ringing, tone signaling and battery. Trunk option selection 
is determined by software control in LD 14.
Application
The optional applications, features and signaling arrangements for each trunk 
are assigned through unique route and trunk data blocks. Refer to the 
Features and Services (553-3001-306) for information about assigning 
features and services to trunks.
Low DC loop resistance dur-
ing outpulsing
N/A
300 ohms
High DC loop resistance
N/A
Ground start equal to or 
greater than 30 kS. Loop start 
equal to or greater than 5 MS
Line leakage
Equal to or greater than 30 
kS (Tip to Ring, Tip to GND, 
Ring to GND).
Equal to or greater than 30 
kS (Tip to Ring, Tip to GND, 
Ring to GND)
Effective loss
See pad table
See pad table
Table 119
Electrical characteristics  (Part 2 of 2)
Characteristic
DID Trunk
CO trunk