Nortel Networks Option 11C User Manual

Page of 546
NTRB21 DTI/PRI/DCH TMDI card
Page 459 of 544
Shelf slot assignment
On non-ECM system cabinets, the NTAK20 may be placed in slots 1-9. On 
cabinets NTAK11Dx and NTAK11Fx, the active NTAK20 must be placed in 
slots 1-3 (slots 4-10 may not be used).
Physical description
The NTRB21 card uses a standard IPE-sized (9.5" by 12.5"), multi-layer 
printed circuit board with buried power and ground layers. It is keyed to 
prevent insertion in slot 10. The clock controller daughterboard is fastened by 
standoffs and connectors. 
The NTRB21 card has seven faceplate LEDs. The first five LEDs are 
associated with the NTRB21 card, the remaining two LEDs are associated 
with the clock controller and DCHI daughterboards.
In general, the first five LEDs operate as follows:
During system power up, the LEDs are on.
When the self-test is in progress, the LEDs flash on and off three times, 
then go into their appropriate states, as shown in Table 143