Nortel Networks 4050 User Manual
854 Appendix B Syslog messages
320818-A
lists the System Control Process INFO messages.
About alarm messages
Alarms are sent at a syslog level corresponding to the alarm severity shown in
Alarms are formatted according to the following pattern:
Id: <alarm sequence number>
Severity: <severity>
Name: <name of alarm>
Time. <date and time of the alarm>
Sender: <sender, e.g. system or the Nortel SNAS 4050 device’s IP address>
Cause: <cause of the alarm>
Extra: <additional information about the alarm>
Severity: <severity>
Name: <name of alarm>
Time. <date and time of the alarm>
Sender: <sender, e.g. system or the Nortel SNAS 4050 device’s IP address>
Cause: <cause of the alarm>
Extra: <additional information about the alarm>
When an alarm is cleared, one of the following messages is sent:
•
Alarm Cleared Name=“<Name>” Id= “<ID>” Sender=“<Sender>”
•
Alarm Cleared Id=“<ID>”
Table 191
System control process messages — INFO
Message
Category
Explanation/Action
System started [isdssl-<version>]
INFO
Sent whenever the system control process has been
(re)started.
(re)started.
Table 192
Alarm severity and syslog level correspondence
Alarm severity
Syslog level
CRITICAL
ALERT
MAJOR
CRITICAL
MINOR
ERROR
WARNING
WARNING
*
ERROR