Nortel Networks 4050 User Manual
872 Appendix B Syslog messages
320818-A
Root filesystem repaired -
rebooting
rebooting
ERROR
OS
fsck found and fixed errors. Probably OK.
Server <id> uses default interface
(interface <n> not configured)
(interface <n> not configured)
WARNING
Traffic
Processing
Processing
A specific interface is configured to be used
by the server but this interface is not
configured on the Nortel SNAS 4050.
by the server but this interface is not
configured on the Nortel SNAS 4050.
Set CSWIFT as default
INFO
Start-up
Using CSWIFT SSL hardware acceleration.
Since we use clicerts, force adjust
totalcache size to : <size> per
server that use clicerts
totalcache size to : <size> per
server that use clicerts
INFO
Start-up
Generated if the size of the SSL session
cache has been modified.
cache has been modified.
single_master
ALARM
(WARNING)
(WARNING)
System
Control
Control
Only one master Nortel SNAS 4050 in the
cluster is up and running.
cluster is up and running.
socks error: <reason>
ERROR
Traffic
Processing
Processing
Error encountered when parsing the socks
traffic from the client. Probably a
non-standard socks client.
traffic from the client. Probably a
non-standard socks client.
SOCKS Rejected Domain=”<id>”
User=”<user>” SrcIP=”<ip>”
Request=”<request>”
User=”<user>” SrcIP=”<ip>”
Request=”<request>”
INFO
AAA
The client failed to perform an operation by
using one of the features available under
the portal’s Advanced tab.
using one of the features available under
the portal’s Advanced tab.
socks request: socks version
<version> rejected
<version> rejected
ERROR
Traffic
Processing
Processing
Socks request of version <version>
received and rejected. Most likely a
non-standard socks client.
received and rejected. Most likely a
non-standard socks client.
SOCKS Domain=”<id>”
User=”<user>” SrcIP=”<ip>”
Request=”<request>”
User=”<user>” SrcIP=”<ip>”
Request=”<request>”
INFO
AAA
The client has successfully performed an
operation by using one of the features
available under the portal’s Advanced tab.
operation by using one of the features
available under the portal’s Advanced tab.
software_configuration_changed
EVENT
System
Control
Control
Indicates that release <VSN> (version) has
been <Status> (unpacked/installed/
permanent).
been <Status> (unpacked/installed/
permanent).
software_release_copying
EVENT
System
Control
Control
Indicates that <IP> is copying the release
<VSN> from another cluster member.
<VSN> from another cluster member.
software_release_rebooting
EVENT
System
Control
Control
Indicates that a Nortel SNAS 4050 (<IP>)
is rebooting on a new release (in other
words, a Nortel SNAS 4050 that was not up
and running during the normal installation
is now catching up).
is rebooting on a new release (in other
words, a Nortel SNAS 4050 that was not up
and running during the normal installation
is now catching up).
ssi_mipishere
EVENT
System
Control
Control
Tells that the MIP (management IP
address) is now located at the Nortel
SNAS 4050 with the <IP> host IP address.
address) is now located at the Nortel
SNAS 4050 with the <IP> host IP address.
switch controller:switch
[1:<switchID>] – Added
[1:<switchID>] – Added
INFO
NSNAS
Switch <switchID> has been added to
Domain 1.
Domain 1.
switch controller:switch
[1:<switchID>] - Deleted
[1:<switchID>] - Deleted
INFO
NSNAS
Switch <switchID> has been deleted from
Domain 1.
Domain 1.
Table 204
Syslog messages in alphabetical order (Sheet 8 of 10)
Message
Severity
Type
Explanation