90 Chapter 3 Managing the network access devices
320818-A
 
The HealthCheck menu includes the following options:
Controlling communication with the network access 
devices using the CLI
To stop communication between the Nortel SNAS 4050 and a network access 
device, use the following command:
/cfg/domain #/switch #/dis
Enter 
apply
 to apply the change immediately.
/cfg/domain #/switch #/hlthchk
followed by:
interval <interval>
Sets the time interval between checks for switch 
activity.
interval
 is an integer that indicates the time 
interval in seconds (
s
), minutes (
m
), or hours (
h
). 
The valid range is 60s (1m) to 64800s (18h). The 
default is 1m (1 minute).
deadcnt <count>
Specifies the number of times the Nortel SNAS 4050 
will repeat the check for switch activity when no 
heartbeat is detected.
count
 is an integer in the range 1–65535 that 
indicates the number of retries. The default is 3.
If no heartbeat is detected after the specified number of 
retries, the Nortel SNAS 4050 enters status-quo mode. 
sq-int <interval>
Sets the time interval for status-quo mode, after which 
the network access device moves all clients into the 
Red VLAN.
interval
 is an integer that indicates the time 
interval in seconds (
s
), minutes (
m
), or hours (
h
). 
The valid range is 0 to 64800s (18h). The default is 
1m (1 minute).
Note: If the switch is not going to be used in the Nortel SNA network, 
Nortel recommends deleting the switch from the Nortel SNAS 4050 
domain, rather than just disabling it.