10-106
Surveyor 
User’s Guide
Excessive BOOTP
Counter
The Excessive BOOTP counter increments when a change in the number of 
BOOTP/DHCP requests per second exceeds a threshold. A count of all Excessive 
BOOTP events displays in the 
Overview
 counters of Expert View. A threshold for 
this counter can be set in Expert Alarms.
Expert Symptom
Excessive BOOTP events are automatically logged as expert symptoms. The 
Symptom Summary
 field provides information about the rate of change for BOOTP/
DHCP requests. For example:
Rate of change of Bootp/Dhcp Requests=25
The threshold value for this symptom can be changed. The default threshold is a 
delta of 10 BOOTP/DHCP requests per second. 
Diagnostic Details
__________________________________________________________________ 
Problem Description: 
The expert threshold for the number of BOOTP/DHCP requests has been exceeded 
for this segment.
__________________________________________________________________ 
Probable Cause(s):
1. The network has many devices that are being reset. 
2. The DHCP server has many requests from floating clients.
__________________________________________________________________ 
Recommended Action(s):
1. Load balance your network. Add more DHCP servers.
2. Your network may have just come up after a power down. If so, ignore this 
problem.