Hints and Tips for Expert Features
Double-click any symptom in a table to view Diagnostic information.
When looking at Expert View in Monitor only mode, Frame IDs are displayed 
for information only and you cannot examine a frame related to a symptom. If 
you need to look at specific frames related to Expert Symptoms, look at the 
frame information in the capture buffer or in a capture file.
Expert Views can be disabled on a per module basis. Select 
Module 
 Set-
tings…
 from the 
Configuration
 menu and choose the 
Modes
 Tab. Remove the 
check from the 
Expert Views
 box.
Click, hold, and drag a column border to resize columns in any Expert View 
Table. Increasing the size of the 
Symptom
 column gives you a view of the com-
plete name of the symptom.
Click, hold, and drag a column border to remove columns in any Expert View 
Table. Double-click on the same column border to bring back the display of a 
column.
Duplicate addresses appear both in the Duplicate Network Address Table and as 
a symptom in Expert View.
Thresholds can be set for Expert Symptoms. Select 
Expert Settings…
 from the 
Configuration
 menu and find the symptom you want to change. Some threshold 
values for symptoms cannot be changed.
Expert Symptoms can be selectively disabled. Select 
Expert Settings…
 from the 
Configuration
 menu and find the symptom you want to disable from the tree 
structure. Remove the check from the symptom. Some symptoms cannot be dis-
abled.
Expert Symptoms can be displayed in the Summary field of Capture View. 
From the Configuration menu, select 
Capture View Options 
 Display
 and 
select the 
Display Expert Symptom
 check box. Packets that trigger an expert 
symptom and have expert symptom information will display in reverse video.