Protocol Color Coding
Surveyor provides a real-time protocol decode called Packet Summary View and 
protocol decodes in Capture View. To use these displays more effectively, you may 
want to set the colors used for packet display. For example, you might want to dis-
play all transport layer packets in red and all others in black if you are looking only 
for protocol decode information in the transport layer.
To set up or change color coding for protocol decode, do the following:
1. Choose 
System Settings…
 from the 
Configuration
 menu. Select the 
Protocol 
Color Coding 
tab.
2. Click on a protocol layer.
3. Using the color buttons, set the foreground and background color display for 
the selected protocol.
4. Repeat as required for other protocol layers.
5. Make sure that the 
Use Color Coding
 box is checked.
6. Click the 
OK
 button.
Use the 
Default All 
button to return all color settings to their default values. Use the 
Set Default
 button to reset the default to the colors currently displayed.
Setting Update Timers
Timers control how often counters, tables, and displays are updated. There are two 
types of timers, display timers and polling timers. Remote polling timers control 
how often data is updated from remote systems. Display timers control how often 
displays of data are updated in the Surveyor software. All timer values are in 
seconds.
For local devices, the MAC Layer counters are updated every second, and other 
charts and tables for local devices are updated every 10 seconds. 
To configure the timers, select 
System Settings…
 from the 
Configuration
 menu. 
Select the 
Timers
 tab. The timers are listed and described in Table 4-6, Table 4-7,