Finisar Surveyor User Manual

Page of 454
4-19
Configuring Surveyor
Settings for Analyzer Devices
4
2. Click on the icon for the remote analyzer device in the Resource Browser.
3. Choose 
Properties 
from the 
Host
 menu.
4. Click the 
Reset Host/Image Upgrade 
button.
5. Check the 
Warm Boot
 radio button under 
Reset Options
. Leave all other fields 
blank or unmarked.
6. Click the 
OK
 button.
When you reset a remote analyzer device, you will lose the connection. Use the 
Connect
 option from the 
Remote
 menu to reconnect.
Updating an Analyzer Device
You can update the software or change address information for a Finisar analyzer 
device from Surveyor.
Before you can reset the device with a new image, you must place the new image on 
a server that runs TFTP protocol. 
Download the new software from the support web site, 
http://www.finisar.com
. Go to the software updates section of the Web 
site to find the new analyzer image. Place the software on the server that runs the 
TFTP protocol. 
Before you can update the analyzer address information automatically, you must 
have a server that contains the new address information and runs the BOOTP proto-
col.
Use the following procedure to update the analyzer image software.
1. Login to the remote analyzer device with “super-user” privileges.
2. Click on the icon for the analyzer device in the Resource Browser.
3. Choose 
Properties
 from the 
Host
 menu.
4. Set the new IP Address, IP Gateway Address, and Subnet Mask for the 
analyzer. If no address update is needed, or you are updating the address from 
a BOOTP server, skip this step. 
5. Click the 
Reset Host/Image Upgrade
 button.
6. Check the
 Enable BOOTP
 box if you are updating addresses from a BOOTP 
server.
7. Check the
 Image Upgrade (TFTP)
 box if you are updating addresses from a 
TFTP server.