Finisar Surveyor User Manual

Page of 454
5-6
Surveyor 
User’s Guide
Modes
Modes are applied to resources. Each resource can be in a different mode. The 
modes available with Surveyor depend on the underlying hardware resource as 
shown in Table 5-2 below:
Hardware Devices
The monitor and capture functions look at the same bit stream being received by a 
device. The difference between monitor and capture modes is how the bit stream is 
stored, viewed, and displayed by Surveyor. Because each device has different 
capabilities for storing and viewing the bit stream, you must understand the 
capabilities of the device you are using to completely understand what is possible in 
each mode. 
The capabilities of each hardware device supported by Surveyor are described in 
Table 5-3. See Appendix A for more information on the implementation of 
Surveyor and a summary of all differences between hardware devices.
Table 5-2. Surveyor Resource Modes
Mode
Description
Resource Type
Monitor 
Provides real-time views and decodes 
of packets received by a device. 
All
Capture 
Allows packets received by a device to 
be stored in a buffer for analysis. 
All
Capture + Monitor 
Provides both real-time monitoring 
views and the ability to store packets for 
later analysis.
Viewed/captured packets 
for THGm are identical.
Cap + Disk
Allows packets received by a device to 
be stored in a buffer for analysis and on 
hard disk.
All, used primarily for 
THGsE devices.
Transmit
Allows the transmission of packets from 
a device. You must have the Packet 
Blaster plug-in from Finisar to use 
Transmit mode.
All
(Not recommended for 
NDIS or Portable Analyzer 
Cards)
Capture + Transmit 
Allows simultaneous capture and trans-
mit from the same module.
All
Multi-QoS Only 
Monitor-only mode that provides only 
the Multi-QoS real-time views. The
Multi-QoS only mode is set using the 
Settings option from the Module 
menu.
All