Gateway 820 LTO User Manual

Page of 72
53
SCSI interface
www.gateway.com
Changing the SCSI ID settings 
To change the SCSI ID settings:
1
From the main menu, press the P
REVIOUS
 or N
EXT
 button until 
Configuration
 appears on the LCD.
2
Press E
NTER
 to select the 
Configuration
 menu.
3
Press the P
REVIOUS
 or N
EXT
 button until Change SCSI ID appears on the 
LCD.
4
Press E
NTER
 to select the 
Change SCSI ID
 option.
5
Press the P
REVIOUS
 or N
EXT
 button until Loader or Drive appear on the LCD. 
6
Press E
NTER
 to select the 
Loader
 or 
Drive
 option.
7
Press the P
REVIOUS
 or N
EXT
 button until the SCSI ID you want appears.
8
Press the E
NTER
 button. Cycle Power for New SCSI ID appears on the LCD.
9
Turn off the autoloader. Wait a few seconds, then turn the autoloader on 
again. The selected SCSI ID is now set.
SCSI cable requirements 
We recommend using 68-pin SCSI cables that conform to SCSI-3 specifications.
Important
If you change the SCSI ID, you may also need to turn the 
host server off and on, and reconfigure your backup 
program before you can use the autoloader. The 
autoloader and the tape drive must each have unique 
SCSI IDs. Make sure that you do not assign duplicate IDs 
within a bus.
Warning
All wide SCSI configurations (single-ended, LVD, and 
HVD) use the same 68-pin connector. Attaching the 
autoloader directly to an HVD SCSI will make the entire 
bus non-functional and may permanently damage the drive 
or other SCSI devices on the bus.