GBIC module definition parameters
Module 
Definition 
MOD_DEF(0) 
Pin 4 
MOD_DEF(1) 
Pin 5 
MOD_DEF(2)
Pin 6 
Interpretation by host Reference 
NC 
NC 
NC 
GBIC not present clause   
1 NC  NC 
TTL 
LOW 
Copper Style 1 or Style 2 connector, 1.0625 Gbd, 
100-TW-EL-S or 100-TP-EL-S, active 
inter-enclosure connection and IEEE802.3 
1000BASE-CX 
NC TTL 
LOW NC 
Copper Style 1 or Style 2 connector, 1.0625 Gbd, 
100-TW-EL-S, or 100-TP-EL-S, active or passive 
intra-enclosure connection   
NC 
TTL LOW 
TTL LOW  Optical LW, 1.0625 Gbd 100-SM-LC-L 
TTL LOW 
SCL 
SDA 
Serial module definition protocol 
5 TTL 
LOW NC TTL 
LOW 
Optical SW, 1.0625 Gbd 100-M5-SN-I or 
100-M6-SN-I 
TTL LOW 
TTL LOW 
NC 
Optical LW, 1.0625 Gbd 100-SM-LC-L and similar 
to 1.25 Gbd IEEE802.3z 1000BASE-LX, single 
mode 
TTL LOW 
TTL LOW 
TTL LOW 
Optical SW, 1.0625 Gbd 100-M5-SN-I or 
100-M6-SN-I and 1.25 Gbd, IEEE 802.3z, 
1000BASE-SX 
 
GBIC timing parameters for GBIC management
Parameter Symbol 
Min. Max. Unit Unit 
Conditions 
TX_DISABLE assert time 
t_off 
 
10
µsec
Rising edge of TX_DISABLE to fall of output signal 
below 10% of nominal 
TX_DISABLE negate 
time 
t_on  1 
mec
Falling edge of TX_DISABLE to rise of output 
signal above 90% of nominal 
Time to initialize, 
includes reset of 
TX_FAULT 
t_init  
300 msec
From power on or hot plug fter V DD T > 4.75 volts 
or From negation of TX_DISABLE during reset of 
TX_FAULT. 
TX_FAULT from fault to 
assertion 
t_fault  100
µsec
From occurrence of fault (out-put safety violation or 
V DD T < 4.5 volts) 
TX_DISABLE time to 
start reset 
t_rest 10
 
µsec TX_DISABLE HIGH before TX_DISABLE set LOW
RX_LOS assert delay   
t_loss_on 
 
100
µsec
From detection of loss of signal to assertion of 
RX_LOS 
RX_LOS negate delay 
t_loss_off 
 
100
µsec
From detection of presence of signal to negation of 
RX_LOS