Delta Electronics DVPDU-01 Leaflet

Page of 2
                    
                                    
DVPDU-01 Digital Setup Display 
                                                     
Instruction Sheet 
1  
WARNING 
 
  Please power down the MPU of the 
PLC prior to install the DU-01, which 
is connected via a high-density 
connector.  Also please read the 
figures on the right for operation 
correctly to prevent damage. 
 
 
2  
INTRODUCTION 
 
DU-01 Digital Setup Display has two operation modes, TS-01 and 
TC-01.  The mode selection switch locates at the back of the 
DU-01.  Factory setting is TS-01 mode.  The current operation 
mode will be displayed every time when power up. 
TS-01
 
TC-01
 
Back of the DU-01 
1. In 
TS-01 mode, DU-01 (specified as TS-01 hereof) has the following functions: 
•  Read/Write both the internal devices of PLC (e.g. perpetual calendar, bit devices (X, Y, M, S) 
and word devices (T, C, D)) and the Control Register (CR) inside the extension units. 
•  Support the read/write 32-bit data register.     
•  Set Start-up display and power save mode. 
•  Monitor the devices. 
•  If connect the accessory cable to ES-series without perpetual calendar, the Time Display will 
start from 00-00-00 calculated by the microprocessor of DU-01 (timing error may occur). 
•  Give RUN-STOP command to PLC. 
2. In 
TC-01 mode, DU-01 (specified as TC-01 hereof) has the following functions for DVP all series: 
•  Read/write the program P, data register D and file register F from PLC. 
•  Copy program and data. 
•  Support the PLC password protection. 
 
Overview of the Product - Names of Parts
 
P: program area indication 
(TC-01) 
2  W: write (WR) indication (TC-01) 
3  R: read (RD) indication (TC-01) 
4  “In communication” indication 
D: Data Register indication 
(TC-01) 
F: File Register indication 
(TC-01) 
CR: Control Register indication 
(Extension Module) 
8  ER: Error message display 
9 Display 
Area 
10  Enter button 
 
indication 
11 
K (Decimal), H (Hexadecimal) 
indication 
12 
Contacts & coils of timer / 
counter indications 
13 
Word devices T, C, D, DD 
(32-bit) 
indication 
14  Bit devices X, Y, M, S indication 
15  Digit backspace / Run (TC-01) 
16  Back to previous status 
17  Enter number or select device 
18 Confirm 
ESC
OK
4
3
2
1
5
6
7
8
9
DU-01
 
19  Enter number or select device 
3  
INSTALLATION & WIRING 
 
1.  Direct mounting to the expansion slot in the MPU of 
the EP/EH series 
 
 
 
  Please power down the PLC MPU prior to install the DU-01,
which is connected via a high-density connector. Also please 
refer to the figures above for proper operation.  Put the 
face-up DU-01 slantly in the extension slot, then push it down 
in arrow direction.    DO NOT push it down vertically to prevent
damage. 
2.  Connecting to DVP 
series PLC via accessory 
cable 
 
(No need to shut down the MPU)
 
4  
TS-01 OPERATION 
1. 
Switch DU-01 to TS-01 mode. (Please see the back of the DU-01) 
2. Main 
Process 
OK
ESC
ESC
OK
ESC
ESC
OK
OK
ESC
Time Mode
Press and hold for 3 sec.
Auto Save
Confirm & update time
Operation Mode
Display
Selection
No Save
YY-MM-DD
HH-MM-SS
  Device
Selection
Device Selection
X, Y, M, S
T, C, D
CR
DD(32-bit)
OK
OK
OK
OK
OK
OK
OK
ESC
ESC
ESC
ESC
ESC
  Device
  Monitor
   Bit
Device
 Word
Device
Device confirm
Device confirm
Number Selection
Specify a number
Force On/Off setting
Specified No.
    Display
Enter Set Value
Enter a number
Number Selection
Press
to complete entering & return
Monitor status of 8 consecutive 
devices from the specified number
Press and hold for 3 sec.
Press and hold for 3 sec.
Press and hold for 3 sec.
Press and hold for 3 sec.
 
3. 
Start-up display mode setting (press 
+
 
buttons simultaneously) 
Any mode*
Sleep mode
Monitor 
Mode
Press          + 
Until              shows 
+
Time & device 
content
Sleep mode activated if no button is pressed
within 30 seconds
*Note: not include system operation mode setting
 
4. 
Please see the back page for detail information about the process of each mode.   
5
TC-01 OPERATION 
 
1. Switch the DU-01 to TC-01 
mode (please see the back of 
the DU-01), and select RD (to 
read P, D and F in the MPU of 
PLC) or WR (to write the data 
in P, D, F of DU-01 to the MPU 
of PLC). 
TC-01
Indication of the connected MPU model
Indication of internal data storage model 
Note: P: Program, D: Data register, F: File register 
2. TC-01 Password Key Setting 
Password key setting of TC-01 can be set via WPLSoft. The purpose is to read/write to the key-locked 
PLC as long as the password setting matches with the one in PLC.    To unlock the password key 
setting, please use WPLSoft as well. 
a)  Password Key Setting 
 
In RD or WR mode, press ESC button and hold for 3 seconds or 
more to enter password setting.    See the figure on the right: 
 
Open WPLSoft   [Setting]   [TC-01 password key setting].   
Select [Enter TC-01 password key], and operate as instructed. 
 
After setting, display shows the figure on the right. (KEY SET), 
then press ESC to exit. 
b)  TC-01 has password key setting, therefore, only if the PLC has no password protection or with the 
same password with TC-01 can process the writing.    It also writes the password to the PLC for 
added protection. 
c)  Password key clear (KEY CLR): Same as the operation above. Open WPLSoft, select [TC-01 
password key clear], and operate as instructed. 
3. Clear P, D, F of TC-01: select the device (P, D or F) to be cleared, press
+
 simultaneously, 
then press ESC. 
4.  RD mode description: 
RD read mode
P,D,F selection
+
P(Program)
D (Data Register)
F (File Register)
Reading P (Program).
You can press ESC to 
pause reading.
Setting reading range.
 (default start & end 
addresses are  latched 
area range. User can 
re-set it.) 
Reading F (file register)
You can press ESC to 
pause reading.
Enter start address
Finish reading
Finish reading
Finish reading
Finish reading.
d1EC is the CHKSUM
of writing program
2746 is the CHKSUM
of writing data
Enter end address
Reading processing...
You can press ESC to 
pause reading.
Confirm
Device