Delta Electronics VFD-F Series User Manual

Page of 161
 
VFD-F Series 
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED 
8-1
CHAPTER 8  PARAMETER SUMMARY 
Group 0 AC Drive Status Parameter 
 
Parameters Functions 
Settings 
Factory 
Setting
Customer
 
00-00  Software Version 
Read only 
 
 
 
00-01  AC Drive Status Indication 1 00: No Fault occurred 
01: oc (over current) 
02: ov (over voltage) 
03: oH (over temperature) 
04: oL (overload) 
05: oL1 (electronic thermal relay) 
06: EF (External Fault) 
07: occ (AC drive IGBT fault) 
08: cF3 (CPU failure) 
09: HPF (Hardware Protection 
Failure) 
10: ocA (current exceed during 
Acceleration) 
11: ocd (current exceed during 
Deceleration) 
12: ocn (current exceed during 
Steady State) 
13: GFF (Ground Fault) 
14: Lv (Low voltage) 
15: cF1 (input data abnormal) 
16: cF2 (output data abnormal) 
17: bb (base block) 
18: oL2 (over load2) 
19: Reserved   
20: codE (software or password 
protection) 
21: EF1 (external emergency stop)
22: PHL (phase loss) 
23: Lc (Low current) 
24: FbL (Feedback loss) 
25: Reserved 
26: FAnP (Fan Power Fault) 
27: FF1 (Fan 1 fault) 
28: FF2 (Fan 2 fault) 
29: FF3 (Fan 3 fault) 
30: FF123 (Fan 1, 2, 3 fault) 
31:
 FF12 (Fan 1, 2 fault) 
32: FF13 (Fan 1, 3 fault) 
33: FF23 (Fan 2, 3 fault) 
34: Fv (Gate Drive Low Voltage 
Protect) 
Read