AC Output Reactor Recommended Value
230V, 50/60Hz, 3-Phase
Inductance (mH)
kW HP
Fundamental
Amps
Max. continuous
Amps
3% impedance
5% impedance
0.75 1
8
12
3
5
1.5 2
8
12
1.5
3
2.2 3
12
18
1.25
2.5
3.7 5
18
27
0.8
1.5
5.5 7.5
25
37.5
0.5
1.2
7.5 10
35
52.5
0.4
0.8
11 15 55
82.5
0.25
0.5
15 20 80
120
0.2
0.4
18.5 25
80
120
0.2
0.4
22 30 100
150
0.15
0.3
30 40 130
195
0.1
0.2
37 50 160
240
0.075
0.15
460V, 50/60Hz, 3-Phase
Inductance (mH)
kW HP
Fundamental
Amps
Max. continuous
Amps
3% impedance
5% impedance
0.75 1
4
6
9
12
1.5 2
4
6
6.5
9
2.2 3
8
12
5
7.5
3.7 5
12
18
2.5
4.2
5.5 7.5
18
27
1.5
2.5
7.5 10
18
27
1.5
2.5
11 15 25
37.5
1.2
2
15 20 35
52.5
0.8
1.2
18.5 25
45
67.5
0.7
1.2
22 30 45
67.5
0.7
1.2
30 40 80
120
0.4
0.7
37 50 80
120
0.4
0.7
45 60 100
150
0.3
0.45
55 75 130
195
0.2
0.3
75 100 160
240
0.15
0.23
90
125 160
240
0.15
0.23
110
150 200
300
0.11
0.185
185
250 320
480
0.75
0.125
220
300 400
600
0.06
0.105