Delta Electronics VFD-S User Manual

Page of 185
Appendix B  Accessories|VFD-S Series 
B-12 
Revision August 2008, SE09, SW V2.61
 
B.3.3 Applications for AC Reactor 
Connected in input circuit 
 
Application 1 
Question 
When more than one AC motor drive is 
connected to the same mains power, and one 
of them is ON during operation. 
When applying power to one of the AC motor 
drive, the charge current of the capacitors 
may cause voltage dip. The AC motor drive 
may be damaged when over current occurs 
during operation. 
 
Correct wiring 
M1
M2
Mn
reactor
AC motor drive
AC motor drive
AC motor drive
motor
motor
motor
 
 
Application 2 
Question 
Silicon rectifier and AC motor drive are 
connected to the same power. 
Switching spikes will be generated when the 
silicon rectifier switches on/off. These spikes 
may damage the mains circuit. 
 
Correct wiring 
DC
power
reactor
reactor
AC motor drive
motor
silicon rectifier