Delta Electronics OPEP-33-A4Q1RI User Manual

Page of 14
 
OPEP-33-A4Q1RI
 
DELTA ELECTRONICS, INC.
 
13 Revision: 
S3
12/20/2007
www.deltaww.com
 
Status Bits and Alarm/Warning Flag Bits (2 Wire Address A2h) 
Address  Bit 
Name 
Description 
110 7 
TX 
Disable 
State 
No 
implemented. 
110 6 
Soft 
TX 
Disable 
No 
implemented. 
110 5 
Reserved 
 
110 
RX Rate Select State 
No implemented. 
110 
Soft RX Rate Select 
No implemented. 
110 
TX Fault State 
No implemented. 
110 
Signal Detect State 
No implemented. 
110 0 
Data_Ready_Bar 
No 
implemented. 
111 All 
Reserved 
 
112 
Temp High Alarm 
Set when internal temperature exceeds high alarm level. 
112 
Temp Low Alarm 
Set when internal temperature is below low alarm level. 
112 
Vcc High Alarm 
Set when internal supply voltage exceeds high alarm level.
112 
Vcc Low Alarm 
Set when internal supply voltage is below low alarm level. 
112 
TX Bias High Alarm 
Set when TX Bias current exceeds high alarm level. 
112 
TX Bias Low Alarm 
Set when TX Bias current is below low alarm level. 
112 
TX Power High Alarm 
No implemented for Burst Mode. 
112 
TX Power Low Alarm 
No implemented for Burst Mode. 
113 
RX Power High Alarm 
Set when Received Power exceeds high alarm level. 
113 
RX Power Low Alarm 
Set when Received Power is below low alarm level. 
113 5-0 
Reserved 
Alarm 
 
114-115 All Reserved 
 
116 
Temp High Warning 
Set when internal temperature exceeds high warning level.
116 
Temp Low Warning 
Set when internal temperature is below low warning level. 
116 5 
Vcc 
High 
Warning 
Set when internal supply voltage exceeds high warning 
level. 
116 4 
Vcc 
Low 
Warning 
Set when internal supply voltage is below low warning 
level. 
116 
TX Bias High Warning 
Set when TX Bias current exceeds high warning level. 
116 
TX Bias Low Warning 
Set when TX Bias current is below low warning level. 
116 
TX Power High Warning 
No implemented for Burst Mode. 
116 
TX Power Low Warning 
No implemented for Burst Mode. 
117 
RX Power High Warning
Set when Received Power exceeds high warning level. 
117 
RX Power Low Warning 
Set when Received Power is below low warning level. 
117 5-0 
Reserved 
Warning 
 
118-119 All Reserved 
 
 
Vendor Specific and User Accessible EEPROM (2 Wire Address A2h) 
Address 
# Bytes 
Name 
Description 
120-122 3 Reserved 
 
123 
Password Byte 3 
High order byte of 32 bit password 
124 
Password Byte 2 
Second highest order byte of 32 bit password 
125 
Password Byte 1 
Second lowest order byte of 32 bit password 
126 
Password Byte 0 
Low order byte of 32 bit password 
127 1 
User 
EEPROM 
Select 
“1” selects user writable EEPROM at locations 128-247 
128-247 120 User 
EEPROM 
User 
writable 
EEPROM 
248-255 
Vendor Specific 
Vendor specific control functions