Delta Electronics LCP-10G3A4EDR User Manual

Page of 16
 
 
LCP-10G3A4EDR
 
DELTA ELECTRONICS, INC.
 
11 Revision: 
0B
2008/9/5
www.deltaww.com
 
  Timing parameters for SFP+ management 
Parameter 
Symbol 
Min. 
Max. 
Unit 
Note 
TX_DISABLE Assert time 
t_off 
 
10 
µsec 1 
TX_DISABLE Negate time 
t_on 
 
msec 
Time to initialize 2-wire 
interfase 
t_2w_start_up  
300  msec  3 
Time to initialize 
t_start_up 
 
300 
msec 
Time to initialize cooled 
module 
t_start_up_cooled
 90 
sec 
Time to Power Up to Level 2 
t_power_level2
 
300 
msec 
Time to Power Down from 
Level 2 
T_power_down
 300 
msec 
TX_Fault assert 
TX_Fault_on 
 
msec 
TX_Fault assert for cooled 
module 
TX_Fault_on  
50  msec  7 
TX_Fault Reset 
t_reset 
10 
 
µsec 
Module Reset 
t_module_reset
 
TBD 
msec 
TBD 
RS0, RS1 rate select timing 
for FC 
t_RS0_FC, 
RS1_FC 
 
500 
µsec 
RS0, RS1 rate select timing 
non FC 
t_RS0, t_RS1 
 
10 
msec 
RX_LOS assert delay   
t_los_on 
 
100 
µsec 
10 
RX_LOS negate delay 
t_los_off 
 
100 
µsec 11 
Notes: 
1) 
Rising edge of TX_Disable to fall of output signal below 10% of nominal.
 
2) 
Falling edge of TX_Disable to rise of output signal above 90% of nominal. This only applies in normal 
operation, not during start up or fault recovery.
 
3) 
From power on or negation of TX_Disable.
 
4) 
From power on or TX_Disable negated during power up, or TX_Fault recovery, until non-cooled power 
level 1 part (or non-cooled power level 2 part already enabled at power level 2 for TX_Fault recovery) 
is fully operational. 
 
5)  From falling edge of stop bit enabling power level 2 until non-cooled module is fully operational. 
6)  From falling edge of stop bit disabling power level 2 until module is within power level 1 requirements. 
7)  From Occurrence of fault to assertion of TX_Fault. 
8)  Time TX_Disable must be held High to reset TX_Fault. 
9) From 
assertion 
till stable output. 
10) From Occurrence of loss of signal to assertion of LOS 
11) From Occurrence of presence of signal to negation of RX_LOS.