Delta Electronics VFD-VL User Manual

Page of 251
Appendix B  Accessories
B-44 
Revision Nov. 2008, VLE1, SW V1.03
 
B.11 Safety Relay EMVL-SAF01 
 
 
B.11.1 Functions of the Terminals 
Terminals 
Descriptions 
Specifications 
S1 
+24VDC power Input 
S2 +24VDC, 
reference 
level of the power 
Min. activation voltage: +19Vdc 
Impedance: 720+10%Ω 
Rated power: about 800mW 
S3 
A dry contact of a relay
J1 
S4 
A dry contact of a relay
Rated current: 8 A 
Rated voltage/max. switch voltage: 240/400 VAC
Contact material: AgSnO2 
Contact impedance: 
100 mOhm / 1 A / 24 VDC 
20 Ohm / 10 mA / 5 VDC 
Mechanical endurance: 10x10
6
 cycles 
Rated operation frequency: 6 min
-1
 / 150 min
-1
 
(loaded/unloaded) 
 
B.11.2 Wiring of the Safety Relay 
S3
S4
S2
S1
-
+
Relay
contact
connect to J P19
on the c ontrol board