Delta Electronics VFD-VL User Manual

Page of 251
                                                                                                      Chapter 3 Operation and Start Up|  
Revision Nov. 2008, VLE1, SW V1.03                                                                                                                       3-11
 
 
Pr.10-02 
Encoder Input Type Setting
 
0: Disable 
1: Phase A leads in a forward run command and 
phase B leads in a reverse run command   
2: Phase B leads in a forward run command and 
phase A leads in a reverse run command  
3: Phase A is a pulse input and phase B is a 
direction input. (low input=reverse direction, high 
input=forward direction)  
4: Phase A is a pulse input and phase B is a 
direction input. (low input=forward direction, high 
input=reverse direction)  
5: Single-phase input 
 
3.3.2.4 Step 4 
Multi-step speed settings 
„  Please confirm the total speed steps (high speed, middle speed, low speed, creep, 
inspection and level auto-learning) 
„  Please make sure that the setting of step speeds and the action of the corresponding 
terminals of multi-function input commands are correct. 
„ Setting multi-step speeds in Pr.04-00 to Pr.04-15 
 
 
 
 
 
 
 
 
 
 
 
 
  
 
 
 
 
NOTE: It is recommended to set the max. operating frequency to the half of max. operating 
frequency before confirming the setting of each step speed and the action of the 
corresponding terminals of multi-function input commands. 
Zero Step Speed Frequency 
0.00~120.00Hz 
1st Step Speed Frequency 
0.00~120.00Hz 
2nd Step Speed Frequency 
0.00~120.00Hz 
3rd Step Speed Frequency 
0.00~120.00Hz 
4th Step Speed Frequency 
0.00~120.00Hz 
5th Step Speed Frequency 
0.00~120.00Hz 
6th Step Speed Frequency 
0.00~120.00Hz 
7th Step Speed Frequency 
0.00~120.00Hz 
8th Step Speed Frequency 
0.00~120.00Hz 
9th Step Speed Frequency 
0.00~120.00Hz 
10th Step Speed Frequency 
0.00~120.00Hz 
11th Step Speed Frequency 
0.00~120.00Hz 
12th Step Speed Frequency 
0.00~120.00Hz 
13th Step Speed Frequency 
0.00~120.00Hz 
14th Step Speed Frequency 
0.00~120.00Hz 
Settings of Pr.04-00 to Pr.04-15
15th Step Speed Frequency 
0.00~120.00Hz