A. 
Panel Appearance and Dimensions 
72.2 [2.84]
57.
3
[2.
26]
14.
3
[0.
57]
59
.7
[2
.35]
3.5 [0.14]
35.8 [1.41]
CME-DN01
ADD1 ADD2
SP
500K
250K
125K
BAUD
M OD
NET
UNIT: mm(inch)
1
5
4
3
2
 
 
1. For RS-485 connection to VFD-E 
2. Communication port for connecting DeviceNet network 
3. Address selector 
4. Baud rate selector 
5. Three LED status indicators for monitor 
B. 
Wiring and Settings 
Refer to following diagram for details. 
CME-DN01
ADD1 ADD2
SP
500K
250K
125K
BAUD
MOD
NET
MAC address Date Rate
CAN-L
V+
Empty
pin
CAN-H
V-
1: Reserved  
2: EV     
5: SG+  
6: Reserved 
7: Reserved  
8: Reserved
3: GND 
4: SG-            
   
Setting baud rate 
BAUD
0
 
Switch 
Value 
Baud 
Rate 
0 125K 
1 250K 
2 500K 
Other 
NOT 
used 
 
Setting MAC addresses: 
use decimal system. 
ADD1
ADD2
 
C. Mounting 
Method 
Step1 and step2 show how to mount this communication 
module onto VFD-E. The dimension in the following is for 
your reference. 
 
Dimensions 
UNIT: mm(inch)
 
STEP 1 
 
STEP 2 
 
D. Power 
Supply 
No external power is needed. Power is supplied via 
RS-485 port that is connected to VFD-E. An 8 pins RJ-45 
cable, which is packed together with this communication 
module, is used to connect the RS-485 port between 
VFD-E and this communication module for power. This 
communication module will perform the function once it is 
connected. Refer to the following paragraph for LED 
indications.
 
E. LEDs 
Display 
1.  SP: Green LED means in normal condition, Red LED 
means abnormal condition.   
2.  Module: Green blinking LED means no I/O data 
transmission, Green steady LED means I/O data 
transmission OK. Red LED blinking or steady LED 
means module communication is abnormal. 
3.  Network: Green LED means DeviceNet 
communication is normal, Red LED means abnormal.
 
NOTE
 
Please download the auto EDS generator and user manual 
at http://www.delta.com.tw/industrialautomation/