Delta Electronics CME-USB01 Leaflet

Page of 2
                                                                                                           
2007-07-09
5011659301-SBT1
 
CME-USB01 
USB Interface for VFD-E Series Instruction Sheet
 
 
 Please thoroughly read this instruction sheet before installing option cards and putting them into 
use. 
 The content of this instruction sheet may be revised without prior notice. Please consult our 
distributors or download the most updated version at http://www.delta.com.tw/industrialautomation/. 
X
 Layout 
 
USB Card (CME-USB01) 
 
 
 
Y
 Installation
 
 
Make sure that the AC Motor Drive is powered 
off before operation. DO NOT insert or remove 
the card when the AC Motor Drive is powered 
on. 
 
Please mount the extension card as shown and 
fix it with the screw packed with the card. 
Screw torque: 
Maximum 2kgf-cm
 
 
USB Cable 
USB Type B to CME-USB01
USB Type A to PC 
NOTE
 
 
Refer to Chapter 5: Parameters 9 (Group 9) in 
the user manual for further details. 
Z
 
Specification 
 
Environmental 
 
Operating 
Temperature
-10
o
C to 50
o
C (non-condensing 
and not frozen) 
Storage 
Temperature
-20
o
C to + 60
o
Ambient 
Humidity 
Less than 90%RH   
(non-condensing) 
Installation 
Altitude 
Below 1000m 
Vibration 
Less than 20Hz:   
Maximum 9.81 m/s
2
 (1G);   
20 ~ 50Hz:   
Maximum 5.88 m/s
2
 (0.6G) 
 
NOTE
 
 
Always use this product in a clean indoor 
location free from dust, corrosive gas and liquid. 
 
Inputs/Outputs 
 
Baud Rate 
Supports 4800, 9600, 19200, 
38400, 57600 bps. 
USB 
Specification
USB v1.1 
 
[
 Notes 
 
Please use shielded wires to avoid interferences 
and connect the shield to ground. 
 
To avoid interference, route the extension card 
wires separately and as far away (at least 15cm) 
as possible from other control wires, motor wires 
and power wires, etc. Where these wires must 
cross each other, please make sure they are at 
a 90
angle. 
 
Always use and operate this product within the 
limit of its specifications.