Delta Electronics LCP-4250A4CDR User Manual

Page of 13
 
 
DELTA ELECTRONICS, INC.
 
2 2008/3/18
Rev. 0A
www.deltaww.com
 
Absolute Maximum Ratings 
Parameter Symbol
Min. 
Typ. 
Max. 
Unit 
Note 
Storage Temperature 
T
S
-40   85  ºC 
 
Supply Voltage 
V
CC
0  5  V 
 
 
Recommended Operating Conditions 
Parameter Symbol
Min. 
Typ. 
Max. 
Unit 
Note 
Case Operating Temperature 
T
C
-5  70 ºC 
Supply Voltage 
V
CC
3.135
 3.465
 
 
Electrical Characteristics 
(V
CC
=3.135V to 3.465V) 
Parameter Symbol
Min. 
Typ. 
Max. 
Unit 
Note 
Total Supply Current 
I
CC
 
180 300  mA 
 
Transmitter 
Transmitter Differential Input Voltage 
Vin,pp 
0.5 
 
2.4 
Transmitter Disable Input-High 
V
DISH
2  
V
CC
+0.3
V  
Transmitter Disable Input-Low 
V
DISL
0  0.8 V 
 
Transmitter Fault Pull up Resistor 
R
TX_FAULT
4.7   10  kΩ 3 
Transmitter Fault Output-High 
V
TXFH
2  
V
CC
+0.3
V  
Transmitter Fault Output-Low 
V
TXFL
0  0.8 V 
 
Receiver 
Receiver Differential Output Voltage 
V
out,pp
0.3  
Receiver LOS Load 
R
RXLOS
4.7   10  kΩ 3 
LOS Output Voltage-Low 
V
LOSH
2  
V
CC
+0.3
V  
LOS Output Voltage-High 
V
LOSL
0  0.8 V 
 
Output Data Rise/Fall Time 
t
r
/ t
f
  
120 
psec  5 
Notes:
 
1. 
See Ordering information for detail
   
2.  Internally AC coupled and terminated to 100 Ohm differential load. 
3.  Pull up to V
CC
 on host Board.   
4.  Internally AC coupled, but requires a 100 Ohm differential termination at or internal to Serializer/ Deserializer. 
5.  Unfiltered, 20 – 80%.