Property Description of Range Indicator Element 
Variable 
Limits 
When this option is selected, there is Range n-1 for the user to 
use. n represents the total state numbers and n-1 represents the 
total range numbers. For example, if the read address is $0, and 
the total state number of the element is 5, it indicates that there 
is Range 0~4 for the user to use. Then, the lower limit value of 
Range 0 is $1, the lower limit value of Range 1 is $2 and vise 
versa.  
 
Table 3.7.3 Property Description of Simple Indicator Element 
Property Description of Simple Indicator Element 
For the user’s convenience, simple indicator provides two states (ON/OFF) to let the user change the XOR 
color of the base picture quickly. In the following left example figure, there are simple indicator elements on 
the top of the pipe element. The simple indicator elements will change as shown as the right figure below. 
  
 
Read Address  
The address can be internal memory or the controller address. (Please refer to 
Table 3.2.2 Property Description of General Buttons.) 
Text / Text Size 
Font / Text Color 
The user can set the text, text size, font and text color that provided by Windows® 
to determine the text display on the element. (Please refer to Table 3.2.2 Property 
Description of General Buttons.) 
XOR Color 
It is used to set XOR color of base picture.