Delta Electronics VFD-VE Series User Manual

Page of 291
Chapter 5
 
Troubleshooting| 
5-4
 
Revision August 2008, 03VE, SW V2.04
 
5.5 Over Heat (oH1, oH2, oH3) 
 
AC motor driv e overheats
Heat sink overheats
Check  if temper atur e of heat si nk
is larger than 90
  O
C
No
No
No
Yes
Yes
Yes
Yes
Yes
No
Reduc e load
No
Temperature detection  mal functions.
Please contac t DELTA.
If cooling  fan functions normally
Change cooling fan
Check if cooling fan is jammed
Remove 
obstruc tion
Check  if sur roundi ng temper atur e
is withi n specific ation
Adjust surrounding temperature
to speci fic ati on
Maybe AC motor drive has malfunction or 
misoperation  due to noise. Pleas e contact
DELTA.
If load is too lar ge
 
 
5.6 Overload 
OL1/ OL2
OL
Reduce load or increase the power of AC motor drive
Check if the setting of electronic 
thermal relay is suitable 
Yes
Yes
No
No
Modify setting
If load is too large
Maybe AC motor drive has malfunction
or misoperation due to noise.