Delta Electronics VFD-PU06 Leaflet

Page of 2
 
2007-07-19
5011615002-U6E2
 
VFD-PU06
 
Digital Keypad Instruction Sheet
 
X
Description of the Digital keypad VFD-PU06
 
U
F
H
VFD-PU06
JOG
RUN
RESET
STOP
LED Display
Indicates frequency, voltage, current, user
defined units, read, and save, etc.
Status Display
Display the driver's current status.  
Model Number
STOP/RESET
 
Stops AC drive operation and reset the drive 
after fault occurred.
PU
EXT PU
Right key
Move the cursor to the right
RUN Key
Start  AC drive operation.
Frequency Command
Status indicator
Output Frequency
Status indicator
User Defined Units
Status indicator
JOG
By pressing JOG key,
Jog frequency operation.
MODE
Change between different display mode. 
Left Key
M
ove cursor to the left.
UP and DOWN  Key
Set the parameter number 
and changes the numerical 
data, such as Master Frequency.
FWD/REV Key
Select FWD/REV operation.
 
 
Y
 Explanation of Display Message 
 
Display Message 
Descriptions 
 
The AC motor drive Master Frequency Command. 
 
The Actual Operation Frequency present at terminals U, V, and W. 
 
The custom unit (u) 
 
The output current present at terminals U, V, and W. 
 
Press 
 to change the mode to READ. Press PROG/DATA for about 2 
sec or until it’s flashing, read the parameters of AC drive to the digital keypad 
PU06. It can read 4 groups of parameters to PU06. (read 0 - read 3)   
 
Press 
  to change the mode to SAVE. Press PROG/DATA for about 2 sec 
or until it’s flashing, then write the parameters from the digital keypad PU06 to 
AC drive. If it has saved, it will show the type of AC motor drive. 
 
The specified parameter setting. 
 
The actual value stored in the specified parameter.