8)  Byte 84-91: Date code 
9)  Byte 95: Check sum of bytes 64-94 
10) Byte 128 to 255 had been set hex 00 
 
Digital Diagnostic Monitoring Interface 
Alarm and Warning Thresholds (2-Wire Address A2h) 
Address 
Bytes 
Name 
Value (Dec.) 
Unit 
Note
00-01 2 
Temp 
High 
Alarm 
T
(MAX.)+15 
02-03 2 
Temp 
Low 
Alarm 
T
(MIN.) 
04-05 2 
Temp 
High 
Warning 
T
(MAX.)+10 
06-07 2 
Temp 
Low 
Warning 
T
C  
(MIN.)+10 
 
08-09 
Voltage High Alarm 
Vcc+5% 
10-11 
Voltage Low Alarm 
Vcc-5% 
12-13 
Voltage High Warning 
Vcc+3% 
14-15 
Voltage Low Warning 
Vcc-3% 
Volt 
 
16-17 2 
Bias 
High 
Alarm 
I
OP
+10 
18-19 2 
Bias 
Low 
Alarm 
I
OP
-5 
20-21 2 
Bias 
High 
Warning 
I
OP
+7 
22-23 2 
Bias 
Low 
Warning 
I
OP
-3 
mA 2 
24-25 
TX Power High Alarm 
P+3 
26-27 
TX Power Low Alarm 
P-3 
28-29 
TX Power High Warning 
P+2 
30-31 
TX Power Low Warning 
P-2 
dBm 
32-33 
RX Power High Alarm 
P
0
+3 
34-35 
RX Power Low Alarm 
P
S
-2 
36-37 
RX Power High Warning 
P
0
+2 
38-39 
RX Power Low Warning 
P
S
 
dBm 4 
40-45 
16 
Reversed 
 
 
 
56-91 
36 
External Calibration Constants 
 
 
 
92-94 
Reversed 
 
 
 
95 
Checksum 
 
 
96-97 
Real Time Temperature 
 
 
 
98-99 2 
Real 
Time 
Supply 
Voltage 
 
 
 
100-101 
Real Time Tx Bias Current 
 
 
 
102-103 
Real Time Tx Optical Power 
 
 
 
104-105 
Real Time Rx Received Power 
 
 
 
106-109 
Reserved 
 
 
 
110 
Optional Status/ Control Bits 
 
 
111 
Reserved 
 
 
 
112-119 
Optional Set of Alarm and Warning 
 
 
 
Notes: 
1) T
C
: Case Operating temperature 
2) I
OP
: Operating current at room temperature. The min. setting current is 0 mA. 
3)  P: Operating optical power of transmitter at room temperature. 
4) P
0
: Overload optical power of receiver