Delta Electronics LCP-1250 CWDM User Manual

Page of 14
 
 
 
DELTA ELECTRONICS, INC.
 
2 2008/1/15
Rev. 0A
www.deltaww.com
 
Absolute Maximum Ratings 
Parameter Symbol
Min. 
Typ. 
Max. 
Unit 
Note 
Storage Temperature 
Ts 
-40 
 
85 
ºC 
 
Supply Voltage 
V
CC
 0    5  V 
 
Recommended Operating Conditions 
Parameter Symbol
Min. 
Typ. 
Max. 
Unit 
Note 
Case Operating Temperature 
T
C
 -5 
  70 
ºC 
Supply Voltage 
V
CC
 3.135
  3.465
 
Data 
Rate 
 
 1250   Mbps 
 
Note 1: See order information 
Electrical Characteristics 
 (V
CC
=3.3V 
± 5%) 
Parameter Symbol
Min. 
Typ. 
Max. 
Unit 
Note 
Total Supply Current 
LCP-1250D4xxxRB 
LCP-1250D4xxxRBH 
LCP-1250D4xxxRBT 
I
CCT
 
 
 
 
360 
380 
380 
mA  
Transmitter 
Transmitter Differential Input Voltage 
V
DT
 0.5    2.4  V 
Transmitter Disable Input-High 
V
DISH
2  
V
CC
+0.3
V  
Transmitter Disable Input-Low 
V
DISL
Vee  0.8  V 
 
Transmitter Fault Pull up Resistor 
R
TX_FAULT
4.7  10 kΩ 2 
Transmitter Fault Output-High 
V
TXFH
2  
V
CC
+0.3
V  
Transmitter Fault Output-Low 
V
TXFL
Vee  0.8  V 
 
Receiver 
Receiver Differential Output Voltage 
V
DR
 0.35   
Receiver LOS Load 
R
RXLOS
4.7  10 kΩ 2 
LOS Output Voltage-High 
V
LOSH
2  
V
CC
+0.3
V  
LOS Output Voltage-Low 
V
LOSL
Vee  0.8  V 
 
Output Data Rise/Fall Time 
t
/ t
f
  
260 
psec  4 
Notes: 
1.  Internally AC coupled and terminated to 100Ohm differential load. 
2.  Pull up to V
CC
 on host Board   
3.  Internally AC coupled, but requires a 100Ohm differential termination at or internal to Serializer/ 
Deserializer. 
4.  These are 20%~80% values