Delta Electronics DTE-2DS Leaflet

Page of 2
 
 
DTE Accessory 
Instruction Sheet 
Thank you very much for choosing DTE-2DS. Please read this instruction sheet before using your DTE-2DS to ensure 
proper operation. Keep this instruction sheet handy for quick reference. 
 Warning 
1.  Please hold the plastic terminal when installing DTE-2DS to prevent electrostatic discharge (ESD).   
2.  Prevent dust or metallic debris from falling into the device and cause malfunction. DO NOT modify 
or uninstall DTE-2DS without being permitted. DO NOT use empty terminals.   
3.  When installing DTE-2DS, please make sure the power of DTE main unit is switched off and insert 
DTE-2DS into the correct slot on DTE main unit.   
4.  Make sure you install DTE-2DS correctly before switching on the power; otherwise serious damage 
may occur. 
5. DO 
NOT touch the terminals or repair the device when the power is on; otherwise an electric shock 
may occur. 
 Product Outline & Dimension 
 
 Electrical Specifications 
Input power 
DC +5V 
Power consumption 
Max. 0.5W 
Display 
Single row 7-segment LED display, two 4 bits 
PV: red   SV: green 
Keys 
4 keys for selecting, changing pages and tuning 
Terminal connection 
Can only be inserted into the “Display and Setup Unit” slot on DTE main unit 
 Setting up Parameters 
Switching modes: DTE-2DS is in ”operation mode” when the power is switched on, Press 
 to enter  
“regulation mode”. Press 
  for more than 3 seconds in the operation mode to enter “initial setting 
mode”. Press 
  in the regulation mode or initial setting mode to return to the operation mode.   
PV/SV: Displaying the present value and set value. Use 
  to change the set value. 
How to set up: Use 
  in the three modes to select the parameter to be set up and 
 to 
modify the settings. Press 
  to save the setting. 
How to switch modes by keys and set up parameters:
 
 
Regulation Mode 
Operation Mode 
Initial Setting Mode 
 Select channel 
 
 
Press 
 
V
 
   
Use 
  to set up target 
temperature (SV) 
Press 
 
V
 
  Set up input type 
 
 
Press 
 
V
 
 
A
uto-tuning 
(Set it up when in PID control and 
RUN) 
Press 
 
V
 
  Control loop RUN/STOP 
 
 
Press
 
 
V
 
  Set up temperature unit 
 
 
Press
 
 
V
 
Regulation Mode 
Operation Mode 
Initial Setting Mode 
 PID proportional band 
(Set it up when in PID control) 
 
Press
 
 
V
 
  Set up start pattern 
(Set it up when in PID control) 
 
Press
 
 
V
 
  Set up upper limit of 
temperature 
 
Press
 
 
V
 
  Set up PID Ti value 
(Set it up when in PID control)
 
 
 
Press
 
 
V
 
  Set up start step 
(Set it up when in PID program 
control) 
 
Press 
 
V
 
 
Set up lower limit of 
temperature 
 
 
Press 
 
V
 
  Set up PID Td value 
(Set it up when in PID control) 
 
 
Press
 
 
V
 
 
Set up the position of 
decimal point 
(Not for thermocouple R, S, B type) 
 
Press 
 
V
 
 Select control mode 
 
 
 
Press
 
 
V
 
 or 
 
Set up PD/PID control offset 
(When in PID control, set up PdoF 
when Ti=0. AT sets up ioF 
automatically when Ti≠0.)  
 
Press
 
 
V
 
 or 
   
Without/with group INB 
Set up upper limit of Alarm 1 
 
 
 
Press 
 
V
 
  Set up output 1 
(Heating, cooling or proportional 
output) 
 
 
 
Press 
 
V
 
  Hysteresis for output 1 
(Set it up when in ON/OFF control) 
 
 
Press
 
 
V
 
 or 
 
Without/with group INB 
Set up lower limit of Alarm 1 
 
Press 
 
V
 
  Set up output 2 
(Heating, cooling or alarm output) 
 
 
Press 
 
V
 
 
Hysteresis for output 2 
(Set it up when in ON/OFF control) 
 
 
Press
 
 
V
 
 
Without group INB 
Set up upper limit of Alarm 2 
 
 
Press 
 
V
 
 or
 
 
Without/with group INB 
Set up Alarm 1 mode 
 
Press 
 
V
 
  Control cycle for output 1 
(Set it up when in PID/programmable 
PID/manual control) 
 
Press 
 
V
 
  Without group INB 
Set up lower limit of Alarm 2 
 
 
Press 
 
V
 
  Without group INB 
Set up Alarm 2 mode 
 
 
Press
 
 
V
 
  Control cycle for output 2 
(Set it up when in PID/programmable 
PID/manual control) 
 
Press
 
 
V
 
  For locking the keys on the 
panel 
 
 
Press
 
 
V
 
  Set up copy function 
 
 
 
Press 
 
V
 
 
Ratio of output 1 & output 2 
when in dual output control. 
Pb2 = Pb1 × COEF 
(Set it up when in PID/programmable 
PID + dual output) 
 
Press
 
 
V
 
  For displaying and tuning 
the value of output 1 
(Displayed when in 
PID/programmable PID/manual 
control RUN) 
 
Press
 
 
V
 
 
Select ASCII/RTU communication 
format 
 
 
 
Press
 
 
V
 
 
Set up the overlapped area 
for dual output (dead band)   
(Set it up when in dual output) 
 
 
 
Press
 
 
  For displaying and tuning 
the value of output 2 
(Displayed when in 
PID/programmable PID/manual 
control RUN) 
 
Press
 
 
Z
 Return to “target 
temperature” 
 Set up communication 
address 
 
 
 
 
Press
 
 
V
 
 
For tuning temperature 
offset 
 
Press
 
 
V
 
 
  Set up communication baud 
rate 
 
Press
 
 
V
 
 
Set up upper limit for 
control output 
 
Press
 
 
V
 
 
  Set up data length 
 
 
Press
 
 
V
 
 
Set up lower limit for control 
output 
 
Press 
 
V
 
 
  Set up parity bit 
 
 
Press 
 
V
 
Regulation Mode 
Operation Mode 
Initial Setting Mode 
 
Set up delay time for alarm 
output 
 
Press
 
 
V
 
 
 
Set up stop bit 
 
Press 
 
Z
 Return to “set up input 
type” 
 
For tuning upper limit of 
analog output 
(Displayed when in analog output) 
 
Press
 
 
V
 
 
 
  For tuning lower limit of 
analog output 
(Displayed when in analog output) 
 
Press
 
 
V
 
 
 
 
Set up positive/negative 
proportional output 
(Set it up when in proportional output 
control)  
 
Press
 
 
Z
 Return to 
“auto-tuning” 
 
 
 Types of Input Sensors & Temperature Range 
1.  Set up input sensor: Enter parameter 
  (see “Setting up Parameters” section for details) in 
“initial setting mode” and select an input sensor (see Table 1).   
2.  Set up temperature range: Enter parameter 
 and 
  (see “Setting up Parameters” 
section for details) in “initial setting mode” to set up the temperature range. 
3.  Set up the position of decimal point: Enter parameter 
  (see “Setting up Parameters” section 
for details) in “operation mode”. The position of decimal point will change the temperature range. 
The screen displays only 4 digits; therefore, you have to set “0” in this parameter if you wish to 
display values bigger than 999 or smaller than -99. The setting will not be saved. Default = 1.
 
 
Input Sensor Type 
Display 
Range 
Platinum resistance (Cu50) 
 
-50 ~ 150°C 
Platinum resistance (Ni120) 
 
-80 ~ 300°C 
Platinum resistance (Pt100) 
 
-200 ~ 850°C 
Platinum resistance (JPt100) 
 
-20 ~ 400°C 
Thermocouple TXK type 
 
-200 ~ 800°C 
Thermocouple U type 
 
-200 ~ 500°C 
Thermocouple L type 
 
-200 ~ 850°C 
Thermocouple B type 
 
100 ~ 1,800°C 
Thermocouple S type 
 
0 ~ 1,700°C 
Thermocouple R type 
 
0 ~ 1,700°C 
Thermocouple N type 
 
-200 ~ 1,300°C 
Thermocouple E type 
 
0 ~ 600°C 
Thermocouple T type 
 
-200 ~ 400°C 
Thermocouple J type 
 
-100 ~ 1,200°C 
Thermocouple K type 
 
-200 ~ 1,300°C 
Table 1 
 Setting up Control Output 
For PID Control Application: 
1. Set up 2 outputs: Enter parameter 
 and 
  in “initial setting mode” (see “Setting up 
Parameters” section for details). Set up one of the two parameters as 
 or 
 of control 
output.  
2.  Set up control type: Enter parameter 
  in “initial setting mode” (see “Setting up Parameters” 
section for details) and set it up as 
 (PID) control. 
3. Set up parameters: In “regulation mode” 
 Parameter 
Can be set up when parameter 
  is set as 
 . When 
 is set 
as 
  , the program will calculate parameters 
 , 
 , 
 , 
 and 
 
automatically and save them. 
 Parameter 
 , 
 and 
 .