Delta Electronics LCP-1250RJ3SR-S User Manual

Page of 9
 
 
                                      LCP-1250RJ3SR-S
 
DELTA ELECTRONICS, INC.
 
  Oct. 17. 2007 Rev. 1.02
 
www.deltaww.com
 
Notes: 
1)  TX Fault is not supported and tied to ground. 
2)  TX disable is an input that is used to reset the chip of Gigabit Ethernet PHY inside the copper SFP.    It is pulled 
up within the module with a 4.7 – 10 K Ω resistor. 
Low (0 – 0.8V):   
 
Transmitter on   
(>0.8, < 2.0V):   
 
Undefined 
High (2.0 – 3.465V):   
Transmitter Disabled   
Open: 
 
   Transmitter 
Disabled 
3)  These are the module definition pins.    They should be pulled up with a 4.7K – 10KΩ resistor on the host board.   
The pull-up voltage shall be VccT or VccR.    MOD-DEF 0 is grounded in the module to indicate that the module is 
present.    MOD-DEF 1 and MOD-DEF 2 are the clock and data lines of the two-wire serial interface, respectively. 
4)  LOS (Loss of Signal) is
 not 
supported and tied to ground. 
5)  VeeR and VeeT are internally connected within the copper SFP. 
6)  RD+ and RD- are the received differential outputs, and they are AC-coupled 100Ω differential lines that should be 
terminated with 100Ω (differential) at user’s SERDES.    The AC coupling is done inside the copper SFP and thus 
not required on the host board. The differential voltage swing will be between 250mV and 625 mV, while properly 
terminated. 
7)  VccR and VccT are the receiver and transmitter power supplies, and they are internally connected within the 
copper SFP.    The power rail is defined as 3.3V ±5% at the SFP connector pin.   
8)  TD+ and TD- are the transmitted differential inputs, and they are terminated with 100Ω differential load 
inside the module.  The AC coupling is done inside the module, and thus not required on the host 
board.