CONFIGURATIONS OF THE TERMINALS
COMPUTER INPUT TERMINAL (ANALOG)
Terminal : HDB15-PIN
Connect the display output terminal of the computer to this terminal with the VGA Cable (supplied). When connecting the
Macintosh computer, MAC Adapter (not supplied) is required.
Connect the display output terminal of the computer to this terminal with the VGA Cable (supplied). When connecting the
Macintosh computer, MAC Adapter (not supplied) is required.
5
1
2
3
4
10
9
6
7
8
15
14
13
11
12
Red Input
Ground (Horiz.sync.)
Green Input
Sense 2
Blue Input
Ground (Red)
Ground (Green)
Ground (Blue)
1
5
2
4
3
6
7
8
+5V Power
Horiz. sync.
Ground (Vert.sync.)
DDC Data
Sense 0
Vert. sync.
DDC Clock
9
13
10
12
11
14
15
Pin Configuration
Terminal : Mini DIN 8-PIN
Connect control port (PS/2, Serial or ADB port) on your computer to this connector with Control Cable.
(Control Cable for PS/2 port is supplied, and Control Cables for Serial port and ADB port are not supplied.)
Connect control port (PS/2, Serial or ADB port) on your computer to this connector with Control Cable.
(Control Cable for PS/2 port is supplied, and Control Cables for Serial port and ADB port are not supplied.)
1
2
3
4
5
8
7
6
Pin Configuration
CONTROL PORT CONNECTOR
-----
CLK
DATA
GND
-----
-----
GND
-----
R X D
-----
-----
GND
RTS / CTS
T X D
GND
GND
-----
ADB
-----
GND
-----
-----
-----
GND
PS/2
Serial
ADB
1
2
3
4
5
6
7
8
COMPUTER INPUT TERMINAL (DIGITAL)
Terminal : DVI 24-pin
Connect the display output terminal of the computer to this terminal with DVI cable (for Single Link T.M.D.S. / not supplied).
Connect the display output terminal of the computer to this terminal with DVI cable (for Single Link T.M.D.S. / not supplied).
1
9
17
2
10
18
3
11
19
4
12
20
5
13
21
6
14
22
7
15
23
8
16
24
T.M.D.S. Data2–
No Connect
T.M.D.S. Data2+
No Connect
T.M.D.S. Data2 Shield
DDC Clock
DDC Data
No Connect
1
5
2
4
3
6
7
8
Pin Configuration
T.M.D.S. Data1–
No Connect
T.M.D.S. Data1+
No Connect
T.M.D.S. Data1 Shield
+5V Power
Ground (for +5V)
Hot Plug Detect
9
13
10
12
11
14
15
16
T.M.D.S. Data0–
No Connect
T.M.D.S. Data0+
No Connect
T.M.D.S. Data0 Shield
T.M.D.S. Clock Shield
T.M.D.S. Clock+
T.M.D.S. Clock–
17
21
18
20
19
22
23
24
Vcc
- Data
+ Data
Ground
1
2
3
4
USB CONNECTOR (Series B)
Pin Configuration
Connect USB port terminal on your computer or peripheral equipment to this connector with USB Cable (not supplied).
2
3
4
1